PRODUCT DETAILS
Vitocal 200-G.
Vitocal 200-G 5.6 kW BWC.M 201.B06 Refrigerant circuit with fixed heating output.
Heat pumps with electric drive for central heating and DHW heating in mono mode or dual mode heating systems.
Features:
- Colour: Vitopearlwhite
- Flow temperature up to 65 °C
- Permissible operating pressure: Heating water 3 bar (0.3 MPa)
- Low running costs thanks to high SCOP to EN 14825: up to 5.3 for average climatic conditions and low temperature application (W35)
- Particularly low noise thanks to new sound insulation concept - up to 49 dB(A)
- Mono mode operation for central heating and DHW heating
- Low running costs with high efficiency due to refrigerant cycle diagnostic (RCD) system with electronic expansion valve (EEV)
- Integral instantaneous heating water heater, e.g. for screed drying
- Easy handling as the heat pump module can be quickly removed thanks to push-fit connections.
- Optimised utilisation of power generated on-site by photovoltaic systems
- Web-enabled via Vitoconnect (accessories) for operation and service using Viessmann apps.
Digital heat pump control unit.
Vitotronic 200 Type WO1C, for weather-compensated operation:
- Cylinder temperature controller
- Operation with user prompts
- Integral diagnostic system
- Control of an instantaneous heating water heater
- Control of an additional oil/gas boiler
- Cascade control for up to 5 Vitocal (requires accessories)
- Control of compatible Vitovent ventilation units
- Natural cooling control function (accessories required)
- Swimming pool heating
- Integral checking of the seasonal efficiency/energy statement
- Optimised self-consumption
- Extensions are required for every heating circuit with mixer, additional oil/gas boiler, cooling control function and swimming pool heating (see Accessories).
Standard delivery:
- Brine/water heat pump in a compact casing
- Built in 3-Way divert valve heating / hot water
- Integral high efficiency brine circuit pump (primary circuit)
- Integral high efficiency heating circuit pump (secondary circuit)
- Integral instantaneous heating water heater
- Safety assembly for the heating circuit
- Weather-compensated Vitotronic 200 heat pump control unit with outside temperature sensor
- Electronic starting current limiter and integral phase monitor
- Connection pipes for flow and return of the brine circuit (primary circuit), heating circuit and DHW flow (secondary circuit) for connection at the top.
- Integral E-Heating
Documents
-
Connection Wiring
-
Datasheet
-
Energy Data
-
EU Conformity
-
Installation Service
-
Technical Guide
-
Vitotronic 200-WO1C Service Instructions
Specification
Unit |
BWC 201.B06 |
BWC 201.B08 |
BWC 201.B010 |
---|---|---|---|
Output |
5.8kW |
7.5kW |
10.4kW |
Performance COP |
4.6 |
4.6 |
4.8 |
Seasonal Performance SCOP |
4.8 |
5.2 |
5.3 |
Flow temperature |
65°C |
65°C |
65°C |
Length |
680mm |
680mm |
680mm |
Width |
600mm |
600mm |
600mm |
Height |
975mm |
975mm |
975mm |
Weight |
145kg |
145kg |
145kg |
Coefficient of performance (COP) at operating point B0/W35 to EN 14511 (05/2018) at rated heating output.
Seasonal coefficient of performance (SCOP) under average climatic conditions, low temperature application (W35) to EN 14825.
Buying into Viessmann.
Viessmann Vitocal heat pumps provide customers with the comfort and peace of mind of a free parts and labour repair service subject to the terms and conditions below and the warranty period of your heat pump.
During the period of the warranty, Viessmann will at their option, repair or replace a heat pump free of charge where it suffers a mechanical or an electrical breakdown as a result of defective workmanship or materials, subject to the following conditions and exclusions.
Warranty qualification requirements
For standard warranty of 2 years, you or your installer can register the installation, using the online option available at https://www.viessmann.co.uk/support/heat-pump-warranty-registration.
Great Britain:
In order for your heat pump to qualify for a warranty longer than 2 years, your installation must be registered with Viessmann within 30 days, the model must be valid for a longer warranty and must be installed by a Viessmann Trained Installer.
For the sale of extended warranties, your heat pump installer must be registered as trained by Viessmann, your installer must register your installation within 30 days using the online option available and you must pay for the extended warranty.
Vitocal 200-G Standard Warranty |
Trained Installer Only |
Trained Installer Only |
---|---|---|
Standard 2 year warranty |
Standard 5 year warranty |
7 Year warranty + £Fee |
Viessmann Warranty Overview
REVIEWS
SIZE & FIT
SHIPPING & RETURNS
Returns Policy
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Fusce eros justo, accumsan non dui sit amet. Phasellus semper volutpat mi sed imperdiet. Ut odio lectus, vulputate non ex non, mattis sollicitudin purus. Mauris consequat justo a enim interdum, in consequat dolor accumsan. Nulla iaculis diam purus, ut vehicula leo efficitur at.
Interdum et malesuada fames ac ante ipsum primis in faucibus. In blandit nunc enim, sit amet pharetra erat aliquet ac.
Shipping
Pellentesque ultrices ut sem sit amet lacinia. Sed nisi dui, ultrices ut turpis pulvinar. Sed fringilla ex eget lorem consectetur, consectetur blandit lacus varius. Duis vel scelerisque elit, et vestibulum metus. Integer sit amet tincidunt tortor. Ut lacinia ullamcorper massa, a fermentum arcu vehicula ut. Ut efficitur faucibus dui Nullam tristique dolor eget turpis consequat varius. Quisque a interdum augue. Nam ut nibh mauris.